New generation of the anti-bug sweeping system

DigiScan
EX reveals all the possibilities of your receiver and allows you to perform sweeping procedure at a professional level

External view of the DigiScan EX sweeping system

Features

The software includes wide set of algorithms searching and signal processing
General and precise scanning is performed during the search; this provides accurate measurement of the signal's central frequency
The algorithm of the spectrum analysis qualitatively recognizes signals from the received data
Multi-sector threshold, reference bandscope or combination of the threshold and bandscope can be used
The 'Background pickup' mode allows the operator to register 'Friendly signals' in the database and take the the bandscopes for subsequent use during the search
The built-in microphone and correlation modes provide automatic classification  of signals according to their danger level in both active and passive (covert) order
The Microsoft Access database format provides wide possibilities for processing the results of search - filtering out, sorting, operating the clipboard, generation of reports for printing or creation of the PDF files.
● The
automatic sound recording can be accomplished for the detected signals
The general radio monitoring functions allow the user to scan with a random step and mode, program the resumption conditions and carry out the sound recording
Reliabilty of the system is confirmed by  years of the effective operation on the territory of Ukraine, Russia and many abroad users.
 A new algorithm 'energetic correlation' have been implemented in the new version DigiScan EX S-Pro.  This  method compares levels of signal on the internal and the external antenna. It allows the software to extract signals originating from inside of the premises not depending on the kind of transmission, including the digital and encrypted protocols.  

View of the DigiScan EX software

Specification
Supplied receivers AR8200, AR8600, AR5000A, AR8000, SR2200, IC-R10, IC-R20, IC-PCR1000, IC-PCR1500 and IC-R8500
Frequency range AR8200: 0.5-3000 MHz
IC-PCR1500: 0.01-3300 MHz
Other receivers: plsease refer to the receiver's specification
Very-low frequency range (with DS-Line 2 Pro converter) 5kHz - 12 MHz plus direct listening
Kinds of detected bugging devices In the radiofrequency range: bugging devices installed in a room, car, body-carried, telephone, with autonomous or external power source, FM/AM-modulated, including the spectrum-inverse masking
In the very-low frequency range
: bugging devices using for transmission: AC wires, telephone/alarm lines or infra-red beams
Distance of detection depends on the transmitter's power and ambient obstacles
(5mW transmitter  at a distance up to 100 m)
Speed of scanning (duration of the 50-3000MHz range scanning): AR8200: not less than 20 min
IC
-PCR1500: not less than 7 min
Other receivers: depends on the model
Processing of data
  • Distinguishing signals from the spectrum and splitting them with analysis of the drop level
  • Classification of signals by the danger level based on the test results
  • Comparison of levels on the external and the internal antenna in the automatic mode  (S-Pro only)
Performed tests Passive correlation, semi-passive correlation, active amplitude and spectral correlation, active parametric correlation and harmonic presence test
Actions performed on detection of a danger signal
  • Notification to the operator

  • Marking the signal for report

  • Automatic sound recording

Modes of work
  • 'Pick-up background' - collecting the 'friendly signals' and taking the bandscopes for subsequent use during the search

  • 'Automatic' - execution of the scheduled task list

  • 'Manual' - analysis of results of work

Variants of threshold Multi-sector threshold, reference bandscope or combination
Kinds of tasks in the scheduler 'Search', 'Analysis', 'Scan Range', 'Scan DB' and 'Frequency watch'
General radio monitoring functions Scanning with a random step and mode, programming the resumption conditions and carrying out the sound recording
Sound processing
  • Automatic sound recording of the dangerous signals

  • Automatic sound recording during execution of the radio monitoring tasks with programmable resumption conditions

  • Audio compression (codecs: MP3, ADPCM, GSM, etc.)

  • Voice activation with adjustable level and silence interval

  • Oscilloscope and FFT-spectrograph

Database
  • Format of Microsoft Access (.mdb)

  • Wide possibilities of operation with the data (filtering, sorting and clipboard)

  • Generation of reports (printing or saving in the PDF-file)

  • Export of data into the WORD or EXCEL

Connection to PC USB socket, LINE IN socket of the soundcard
 
Supplied set
  • The DSC-002 controller with the built-in universal interface (levels RS232/TTL) and reference microphone
  • The DigiScan EX software (installation package includes driver for the controller)
  • The DS-L-AR8200 cable for connection of the AR8200 receiver to the controller
  • Cable 'controller-to-PC'
  • AC adapter with an additional jack for AR8200

Please note that you will need a communication receiver to be used with the system. Refer to the specification for the list of the supplied models. The receiver can be obtained from us or a local dealer in your area.


The DSC-002 controller

Optional accessories
  • (1) DS-Line 2 Provery-low frequency converter for checking wires (AC 220V, telephone wires, alarm wires)
  • (2) ANT-LINEantenna for moving away from the laptop computer in order to avoid interferences
  • (3) IR-LINEprobe for checking the infra-red range (search of bugging devices transmitting information with the help of the IR beams). Connection to the DS-LINE.
  • (4) MLP-LINEprobe for checking the electromagnetic range (checking items for presence of internal electronics)
  • (5) DS CASE – carrying case for the system
  • (6) DS CASE PELIcarrying case with an increased reliability
  • DS-L-ICR20 – cable for connection of the IC-R10/R20 receiver to the controller
  • DS-L-RS232 – cable for connection of other types of receivers to the controller (receivers with the RS232 socket)
  • DS-L-SND sound cables for all the receivers excluding the IC-R20 and AR8200
  • DS-RMexternal reference microphone with a 10m cable. Can be used for checking remote premises. Please note that a built-in reference microphone is already supplied with the system
Computer demands
  • Processor not lower than Pentium 500MHz
  • RAM not less than 256 Mb
  • OS Windows 2000/XP
  • LINE IN input in the soundcard (for correlation)
  • One free USB port
 
Editions of the software
DigiScan EX Standard Searching for listening devices with a scheduler and a number of extra features 
DigiScan EX Professional  Solving both searching and monitoring tasks on a professional level
DigiScan EX S-Pro  Solving both searching and monitoring tasks on a professional level plus energetic correlation (comparison of levels on the external and the internal antenna)

Feature

DigiScan EX Standard

DigiScan EX Professional

DigiScan EX S-Pro

Scheduler

+

+

+

Watchdog timer

+

+

+

Kinds of executed tasks

 

 

 

‘Search’ task: searching for listening devices in a specified frequency range, performing tests to estimate a signal’s danger level, saving signals in the database (DB) and automatic sound recording on a signal’s frequency

 

+

 

+

 

+

Task ‘Analysis’: testing signals in the DB in order to measure their danger level, automatic recording of sound from dangerous signals

+

+

+

Task ‘Scan range’: scanning of a specified frequency range with operator-determined step and modulation, saving signals in the DB. Programmable conditions of continuation and automatic recording of sound

 

 

+

 

+

Task ‘Scan DB’: scanning signals of the DB for their activity, programmable conditions of continuation and automatic recording of sound

 

 

+

 

+

Task ‘Frequency watch’: watching a frequency for activity, programmable conditions of continuation and automatic recording of sound

 

+

+

Search features

 

 

 

Comparison od signals on external and internal antenna (energetic correlation)

 

 

+

Classification of the signals by danger level

+

+

+

Collecting and working with friendly signals to increase speed

+

+

+

Using a reference bandscope as a threshold to increase speed

 

+

+

Silent search in passive modes

+

+

+

Checking wires for the presence of acoustics in the very low frequency range of 5KHz…2MHz: AC 220V, phone lines, alarms. Checking of the infra-red range is also possible (optional probe is required)

+

+

+

Passive amplitude correlation

+

+

+

Semi-passive amplitude correlation

+

+

+

Active amplitude correlation

+

+

+

Active spectrum correlation

+

+

+

Active parametrical correlation

+

+

+

Harmonic presence test

+

+

+

Automatic recording of sound from dangerous signals

+

+

+

Automatic printing of dangerous signals

+

+

+

Notification to the operator about danger detection

+

+

+

Estimation of the bug’s location in 2 dimensions and printout of the results

+

+

+

Monitoring features

 

 

 

Programmable conditions of the scan suspension and resumption

 

+

+

Using a reference bandscope as a threshold to increase the scan speed

 

+

+

Sound recording

 

 

 

Sound archive stores the frequency, modulation, date/time, duration and DTMF. Automatically erases older sound files when the allowed occupied space is exceeded. Export of sound files is possible.

+

+

+

Bit rate selection (9kHz, 16kHz, 22kHz, 44kHz)

+

+

+

Compression of sound with the help of the following codecs: MP3, ADPCM, GSM, etc. The minimum disk space required for 1 hour is 8Mb (80 Mb without compression).

 

+

+

Recognition of the DTMF

 

+

+

Activation by voice with tunable sensitivity and interval

 

+

+

Database

 

 

 

Microsoft Access .mdb format

+

+

+

Export of signals to Microsoft Excel or a text file

+

+

+

Printout of signals and their spectrums

+

+

+

Support of banks and filtering by bank

 

+

+

Selection of the working style: ‘Search’, ‘Monitoring’, ‘Expert’

 

+

+

 
 

New version "S-Pro"

Uses energetic correlation for comparison of level on the internal and the external antenna
Detects signals originating from the inside of the premises including the digital transmissions
Uses the antenna switcher built-in the new convertor DS-Line 2 Pro
ANT-Line 25 is the recommended antenna

Features of the new edition (2.1)

The system works without a HASP key
The DSC-002 controller has been added to the supplied set. Its functionality includes interfacing the receiver, software protection and the reference microphone
Decreased number of cables and adapters. This improved portability and duration of the system's preparation for the work
All the components are connected to the computer via a USB port
The controller contains universal interface for all supplied receivers (levels TTL/RS232, CI-V)
The cable for the AR8200 is included in the supplied set
Added support of new receivers ICOM IC-PCR1500 and AOR SR2200.

Download

Specifications in the Adobe Acrobat (PDF) format
Software (works in a demo mode without the controller)
User manual in the Adobe Acrobat (PDF) format
High-resolution picture of the system
High-resolution picture of the DSC-002 controller

Compatibility

Windows 2000
Windows XP Windows 2003
Windows Vista

 

 
 Copyright DigiScan Labs 1998-2009