DigiScan EX
New generation
of the anti-bug sweeping system |
DigiScan
EX
reveals all the possibilities of your receiver
and allows you to perform sweeping procedure at
a professional level
 |
|
External view of the
DigiScan EX
sweeping system |
|
Features |
●
The software includes
wide set of algorithms searching and signal
processing
●
General
and precise scanning is performed during
the search; this provides accurate
measurement of the signal's central
frequency
●
The
algorithm of the spectrum analysis
qualitatively
recognizes signals from the received
data
●
Multi-sector
threshold, reference bandscope or
combination of the threshold and
bandscope can be used
●
The 'Background pickup' mode allows the
operator to
register
'Friendly signals' in the database and
take the the bandscopes for subsequent
use during the search
●
The
built-in microphone and correlation
modes provide automatic classification
of signals according to their danger
level in both active and passive
(covert) order |
● The
Microsoft Access database format
provides wide possibilities for
processing the results of search -
filtering out, sorting, operating the
clipboard, generation of reports for
printing or creation of the PDF files.
● The
automatic sound
recording can be accomplished for the
detected signals
●
The
general radio monitoring functions allow
the user to scan with a random step and
mode, program the resumption conditions
and carry out the sound recording
●
Reliabilty of the
system is confirmed by years of
the effective operation on the territory
of Ukraine, Russia and many abroad
users.
●
A
new algorithm 'energetic correlation'
have been implemented in the new version
DigiScan EX S-Pro.
This
method compares levels of signal on the
internal and the external antenna. It
allows the software to extract signals
originating from inside of the premises
not depending on the kind of
transmission, including the digital and
encrypted protocols.
|
|
|
 |
|
View of the
DigiScan EX
software |
|
Specification |
|
Supplied receivers |
AR8200,
AR8600, AR5000A, AR8000,
SR2200, IC-R10, IC-R20, IC-PCR1000,
IC-PCR1500 and
IC-R8500 |
|
Frequency range |
AR8200: 0.5-3000 MHz
IC-PCR1500: 0.01-3300 MHz
Other receivers: plsease refer to the
receiver's specification |
|
Very-low frequency range
(with
DS-Line 2 Pro converter) |
5kHz
- 12
MHz plus direct listening |
|
Kinds of detected
bugging devices |
In the
radiofrequency range:
bugging devices
installed in a room, car, body-carried,
telephone, with autonomous or external
power source,
FM/AM-modulated,
including the spectrum-inverse masking
In the very-low
frequency range:
bugging devices using
for transmission: AC wires,
telephone/alarm lines or infra-red beams |
|
Distance of detection |
depends on the
transmitter's power and ambient
obstacles
(5mW transmitter
at a distance
up to 100 m) |
|
Speed of scanning
(duration of the
50-3000MHz
range scanning): |
AR8200:
not less than 20
min
IC-PCR1500:
not
less than 7 min
Other receivers: depends on the model
|
|
Processing of data |
-
Distinguishing
signals from the spectrum and
splitting them with analysis of the
drop level
-
Classification of signals by the
danger level based on the test
results
-
Comparison of levels on the external
and the internal antenna in the
automatic mode
(S-Pro
only)
|
|
Performed tests |
Passive correlation,
semi-passive correlation, active
amplitude and spectral correlation,
active parametric correlation and
harmonic presence test |
|
Actions performed on detection of a
danger signal |
-
Notification to the operator
-
Marking the signal for report
-
Automatic sound recording
|
|
Modes of work |
-
'Pick-up background' - collecting
the 'friendly signals' and taking
the bandscopes for subsequent use
during the search
-
'Automatic' - execution of the
scheduled task list
-
'Manual' - analysis of results of
work
|
|
Variants of threshold |
Multi-sector
threshold, reference bandscope or
combination |
|
Kinds
of tasks in the scheduler |
'Search', 'Analysis',
'Scan Range', 'Scan DB' and 'Frequency
watch' |
|
General radio monitoring functions |
Scanning with a
random step and mode, programming the
resumption conditions and carrying out
the sound recording |
|
Sound processing |
-
Automatic sound recording of the
dangerous signals
-
Automatic sound recording during
execution of the radio monitoring
tasks with programmable resumption
conditions
-
Audio compression (codecs:
MP3,
ADPCM,
GSM,
etc.)
-
Voice activation with adjustable
level and silence interval
-
Oscilloscope and FFT-spectrograph
|
|
Database |
-
Format of
Microsoft Access
(.mdb)
-
Wide possibilities of operation with
the data (filtering,
sorting and
clipboard)
-
Generation of reports (printing or
saving in the
PDF-file)
-
Export of data into the
WORD
or
EXCEL
|
|
Connection to PC |
USB
socket,
LINE IN
socket of the soundcard |
|
| |
|
Supplied set |
-
The
DSC-002
controller with the
built-in universal interface (levels
RS232/TTL)
and reference microphone
-
The
DigiScan EX
software (installation
package includes driver for the controller)
-
The
DS-L-AR8200
cable for connection of
the
AR8200
receiver to the controller
-
Cable 'controller-to-PC'
-
AC adapter
with an additional jack for
AR8200
Please note that you will need a
communication receiver to be used with
the system. Refer to the specification
for the list of the supplied models. The
receiver can be obtained from us or a
local dealer in your area.
|

The
DSC-002 controller |
|
|
Optional accessories |
-
(1)
DS-Line
2 Pro
– very-low
frequency converter for checking
wires (AC 220V,
telephone wires,
alarm wires)
-
(2)
ANT-LINE
– antenna for
moving away from the laptop computer
in order to avoid interferences
-
(3)
IR-LINE
– probe for
checking
the infra-red range (search of
bugging devices transmitting
information with the help of the IR
beams).
Connection to the DS-LINE.
-
(4)
MLP-LINE
– probe for
checking the electromagnetic range
(checking items for presence of
internal electronics)
-
(5)
DS CASE –
carrying case for the system
-
(6)
DS CASE PELI
– carrying case
with an increased reliability
-
DS-L-ICR20
– cable for
connection of the
IC-R10/R20
receiver to the
controller
-
DS-L-RS232
– cable for
connection of other types of
receivers to the controller
(receivers with the RS232 socket)
-
DS-L-SND
–
sound cables for all the receivers
excluding the IC-R20 and AR8200
-
DS-RM
– external
reference microphone with a 10m
cable. Can be used for checking
remote premises. Please note that a
built-in reference microphone is
already supplied with the system
|
 |
|
|
Computer demands |
-
Processor
not lower than
Pentium 500MHz
-
RAM not
less than
256
Mb
-
OS
Windows 2000/XP
-
LINE IN
input in the soundcard (for correlation)
-
One free
USB
port
|
| |
|
Editions of the software |
|
DigiScan EX Standard |
Searching for listening devices with a
scheduler and a number of extra features |
|
DigiScan
EX
Professional |
Solving both searching and monitoring tasks
on a professional level |
|
DigiScan
EX
S-Pro |
Solving both searching and monitoring tasks
on a professional level plus energetic
correlation (comparison of levels on the external and the internal
antenna) |
|
|
Feature |
DigiScan EX Standard |
DigiScan EX Professional |
DigiScan EX S-Pro |
|
Scheduler |
+ |
+ |
+ |
|
Watchdog timer |
+ |
+ |
+ |
|
Kinds of executed tasks |
|
|
|
|
‘Search’ task: searching for listening devices in a
specified frequency range, performing tests to estimate a
signal’s danger level, saving signals in the database (DB)
and automatic sound recording on a signal’s frequency |
+ |
+ |
+ |
|
Task ‘Analysis’: testing signals in the DB in order to
measure their danger level, automatic recording of sound
from dangerous signals |
+ |
+ |
+ |
|
Task ‘Scan range’: scanning of a specified frequency range
with operator-determined step and modulation, saving signals
in the DB. Programmable conditions of continuation and
automatic recording of sound |
|
+ |
+ |
|
Task ‘Scan DB’: scanning signals of the DB for their
activity, programmable conditions of continuation and
automatic recording of sound |
|
+ |
+ |
|
Task ‘Frequency watch’: watching a frequency for activity,
programmable conditions of continuation and automatic
recording of sound |
|
+ |
+ |
|
Search features |
|
|
|
|
Comparison od signals on
external and internal antenna (energetic correlation) |
|
|
+ |
|
Classification of the signals by danger level |
+ |
+ |
+ |
|
Collecting and working with friendly signals to increase
speed |
+ |
+ |
+ |
|
Using a reference bandscope as a threshold to increase speed |
|
+ |
+ |
|
Silent search in passive modes |
+ |
+ |
+ |
|
Checking wires for the presence of acoustics in the very low
frequency range of 5KHz…2MHz: AC 220V, phone lines, alarms.
Checking of the infra-red range is also possible (optional
probe is required) |
+ |
+ |
+ |
|
Passive amplitude correlation |
+ |
+ |
+ |
|
Semi-passive amplitude correlation |
+ |
+ |
+ |
|
Active amplitude correlation |
+ |
+ |
+ |
|
Active spectrum correlation |
+ |
+ |
+ |
|
Active parametrical correlation |
+ |
+ |
+ |
|
Harmonic presence test |
+ |
+ |
+ |
|
Automatic recording of sound from dangerous signals |
+ |
+ |
+ |
|
Automatic printing of dangerous signals |
+ |
+ |
+ |
|
Notification to the operator about danger detection |
+ |
+ |
+ |
|
Estimation of the bug’s location in 2 dimensions and
printout of the results |
+ |
+ |
+ |
|
Monitoring features |
|
|
|
|
Programmable conditions of the scan suspension and
resumption |
|
+ |
+ |
|
Using a reference bandscope as a threshold to increase the
scan speed |
|
+ |
+ |
|
Sound recording |
|
|
|
|
Sound archive stores the frequency, modulation, date/time,
duration and DTMF. Automatically erases older sound files
when the allowed occupied space is exceeded. Export of sound
files is possible. |
+ |
+ |
+ |
|
Bit rate selection (9kHz, 16kHz, 22kHz, 44kHz) |
+ |
+ |
+ |
|
Compression of sound with the help of the following codecs:
MP3, ADPCM, GSM, etc. The minimum disk space required for 1
hour is 8Mb (80 Mb without compression). |
|
+ |
+ |
|
Recognition of the DTMF |
|
+ |
+ |
|
Activation by voice with tunable sensitivity and interval |
|
+ |
+ |
|
Database |
|
|
|
|
Microsoft Access .mdb format |
+ |
+ |
+ |
|
Export of signals to Microsoft Excel or a text file |
+ |
+ |
+ |
|
Printout of signals and their spectrums |
+ |
+ |
+ |
|
Support of banks and filtering by bank |
|
+ |
+ |
|
Selection of the working style: ‘Search’, ‘Monitoring’,
‘Expert’ |
|
+ |
+ |
|
| |
|
|
|
New version
"S-Pro" |
●
Uses
energetic correlation for comparison of level on
the internal and the external antenna
●
Detects signals originating from the inside of
the premises including the digital transmissions
●
Uses the
antenna switcher built-in the new convertor
DS-Line 2 Pro
●
ANT-Line 25 is
the recommended antenna |
|
|
|
Features of
the new edition (2.1) |
●
The system
works without a HASP key
●
The DSC-002
controller has been added to the supplied set.
Its functionality includes interfacing the
receiver, software protection and the reference
microphone
●
Decreased
number of cables and adapters. This improved
portability and duration of the system's
preparation for the work
●
All the
components are connected to the computer via a
USB port
●
The controller
contains universal interface for all supplied
receivers (levels
TTL/RS232,
CI-V)
●
The cable for
the
AR8200
is included in the supplied set
●
Added support
of new receivers
ICOM IC-PCR1500
and
AOR SR2200. |
|
|
|
Download |
|
|
|
|
|
Compatibility |
 |
Windows 2000
Windows XP Windows 2003
Windows Vista |
|
|